GoMarina Access UI
GoMarina Access
Installation guide


GoMarina Access CM

ACU User Interface (UI)
Module
Physical Characteristics
---
​
Dimensions, WxHxD
92x302x43 mm
Operating temperature range
-20..+55 C
Protection level
IP55 (dust & water jet protected), drainage in the bottom
​
User input devices
12-key tactile keypad, QR code reader
Display
2.7" reflective color display with backlight
​
Radios
LTE Cat. M1 or 2G or WiFi with built-in antenna, Bluetooth, NFC tag
ACU Contactor Module (CM)
Physical Characteristics
---
​
Dimensions, WxHxD
72x110x76 mm
Operating temperature range
-40..+55 C
​
Input Power Characteristics
---
​
Connection type
screw terminals, max 2.5 mm^2 wire cross section
Voltage range at L, N terminals
100-240 V AC
Continuous current, max.
0.45 A
​
Average power consumption, ACU UI
2 W
Average power consumption, ACU UI + CM
3 W
​
Appliance class
Class I (requires protective earth connection)
CE Mark Qualification
---
​
ACU UI + CM has been tested according to the requirements of the following standards:
- EN 61000-6-2:2005 Electromagnetic Compatibility (EMC), Part 6-2: Generic Standards - Immunity for industrial environments.
- EN 61000-6-4:2007/A1:2011 Electromagnetic Compatibility (EMC), Part 6-4: Generic Standards Emission standard for industrial environments.
- EN 61000-3-2:2014 Electromagnetic Compatibility (EMC), Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16A per phase).
- EN 61000-3-3:2014 Electromagnetic Compatibility (EMC), Part 3: Limits - Section3: Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current ≤ 16A.
- Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
​
​
​
ACU UI alone (no CM) has been tested for
---
- EN 61000-6-3:2007/A1:2011/AC:2012 Electromagnetic Compatibility (EMC), Part 6-3: Generic Standards - Emission standard for residential, commercial and light-industrial environments
​
​
The radio module and antenna in ACU UI has been tested for, whatever is applicable
---
- EN 300 328 V2.1.1 (2016-11) Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU.
- EN 301 908-1 V11.1.1(2016-07) IMT cellular networks; Harmonised Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 1: Introduction and common requirements.


ACU User Interface (UI)
​
---
​
ACU UI Package Content
- ACU UI Module.
- Stickers with numbers 1, 2.
ACU UI Installation
ACU UI can be used in most environments, including residential, commercial and light-industrial environments.
Do not install ACU UI inside a metal cabinet, because it would block radio signals to and from the built-in antenna.
ACU UI shall be mounted on a flat wall. For mouning on a rounded surface use ACU pedestal mount (PM). The mounting height shall
be chosen so that a standing person, as well as a wheelchair user, is comfortable reaching the keypad and reading from the
display.
Use four screws (not included) to fasten the ACU UI to the wall. Distance between mounting screws, WxH: 55x232 mm.
Apply the included number stickers to the products controlled by ACU.
​
ACU Contactor Module (CM)
---
​
ACU CM Package Content
- ACU Contactor Module.
- Cat 5E cable, 0.9 m.
- Ferrite snap-on core.
- Stickers with numbers 3-5.
ACU CM Installation
ACU CM shall be installed into an outdoor power post. Do not use ACU CM in residential environments.
ACU CM is mounted on a standard 35 mm DIN rail. There are two compression springs pressing the CM against the DIN rail. In order
to install the CM, put the bottom part onto the DIN rail first, then push the CM up and fit the top part onto the DIN rail.
It is also possible to mount CM to a wall using two cheese-headed 3.5 mm screws placed 54 mm apart on a horisontal line.
Install the included ferrite snap-on core onto the Cat 5E cable. The ferrite shall be placed inside the ACU UI module housing
and the cable shall be fastened with a cable tie near the ferrite.
Apply the included number stickers 1-4 to the power post outlets. The outlet numbers must match screw terminal numbering at the CM module
​
Outlet 1 : L12 and N12
Outlet 2 : L22 and N22
Outlet 3 : L32 and N32
Outlet 4 : L42 and N42
​
​
Wiring
---
​
Use one of the following connection charts depending on the use case.
Max. wire length for all connections is 3 meters:
​
Chart P1 - Power Post with Four 16A Outlets and Light.
Chart P2 - Power Post with Six 16A Outlets.
Chart P3 - Power Post with Ten Outlets and 24 V DC Contactors
Chart P11 - Power Post with Two Three-Phase 400V Outlets
Chart R1 - Eight General-Purpose 10A 250V Relays
Chart D1 - Door Lock, 24 V DC.
Chart D21 - Door Lock with Button Input, 24 V DC
Chart D22 -T wo Door Locks with Button Inputs, 24 V DC
Chart S3 - Two Showers, 24 V AC.
Chart B1- Gate Barrier, 24 V DC, with Feedback.
Chart B2 - Gate Barrier, 24 V DC.
Chart W1 - Electrolux Washer or Dryer with I/O Module Type 2, I/O Function A or K
Chart W2 - Two Electrolux Washers or Dryers with I/O Modules Type 2, I/O Function A or K
Chart W3 - Three Electrolux Washers or Dryers with I/O Modules Type 2, I/O Function A or K
Chart W4 - Four Electrolux Washers or Dryers with I/O Modules Type 2, I/O Function A or K
Chart W11 - Electrolux Washer or Dryer with I/O Module Type 2, I/O Function B
Chart W12 - Two Electrolux Washers or Dryers with I/O Modules Type 2, I/O Function B
Chart M1 - Three-Phase 400V Motor with Auxiliary Connection.

Comissioning
---
​
When installation and connection is finished, apply power. ACU shall boot into delivery mode.
Follow instructions on the screen and press buttons to test activation of the connected equipment
from the ACU.
Then send the ACU serial number with the connection chart number to GoMarina for final
configuration. Leave the ACU powered on.